Single-zone Address Module
Bus-Based Zone Expansion for Remote Intrusion Detection Devices, Compatible with AS-9000 Series Intrusion Alarm Control Panels
Type: AS-201
Related: Alarm Panel
The AS-201 Single-Zone Address Module is a bus-connected expansion component that adds one detection zone to a compatible AS-9000 series alarm control panel and allows a remote intrusion detector or other compatible detection device to be wired into that system.
Target Buyers: Importers · Distributors · Wholesalers · Security System Integrators · Security Equipment Suppliers
Core Applications: Intrusion alarm zone expansion · Remote detector connection · Perimeter defense · Security system expansion projects
Key Specifications: DC 10–24 V · 10 mA · Single-zone expansion · Bus communication · 100–299 zone address range · 60 × 16 × 10 mm · 10 g
1. Product Overview
The AS-201 Single-Zone Address Module provides a bus-connected method of expanding an AS-9000 series alarm control panel with one additional detection zone.
The module uses an address-code setting mechanism and communicates with the panel through the alarm-panel bus signal lines. Once wired, the panel can run a bus-device search from the keypad to detect connected modules automatically. Each module carries a unique internal code number; if a duplicate code is detected across modules, the panel can automatically reassign the affected module starting from address 399.
Main Functions
- Single-zone alarm expansion
- Bus communication with AS-9000 series alarm control panels
- Connection of normally open (NO) and normally closed (NC) detection devices
- Address-code configuration
- Automatic bus-device search
- Duplicate-code identification and reassignment
- Compact installation format
- Communication status indication
2. Key Technical Features
Bus Communication
The AS-201 communicates with the AS-9000 series alarm control panel exclusively through the panel’s bus signal lines. This is a proprietary bus interface documented for the AS-9000 system; it is not an Ethernet, IP, wireless, or cloud communication interface.
Single-Zone Detection Input
Accepts detection devices with normally open (NO) or normally closed (NC) outputs.
Address-Code Configuration
The module uses a physical address-code setting switch.
Communication Status Indicator
A blinking indicator confirms normal module communication with the panel.
Compact Form Factor
60 × 16 × 10 mm, 10 g — suitable for discreet installation near the detection point.
3. AS-9000 Compatibility & Bus Communication
| Item | Detail |
| Compatible Panel | AS-9000 Series Alarm Control Panel |
| Communication Method | Alarm control panel bus (proprietary, wired) |
System integrators evaluating the AS-201 for a project should confirm the AS-9000 configuration currently deployed or planned before specifying this module.
Related resource: AS-9000 Series Alarm Control Panel Documentation
4. Detection Device Connection
The AS-201 accepts one remote detection device per module, using either:
- Normally Open (NO) output, or
- Normally Closed (NC) output
The specific detector model and its electrical interface should be checked against project requirements before deployment.
5. Wiring Interface
The AS-201 provides six wires for power, bus communication and detection-device connection.
| Wire Color | Connection |
| Red | Positive power supply |
| Black | Negative power supply |
| Green | Alarm control panel bus (positive) |
| Yellow | Alarm control panel bus (negative) |
| Blue | Detection equipment NC |
| White | Detection equipment COM |
Wiring should be carried out according to the AS-201 and AS-9000 system documentation.
6. Address Code & Zone Identification
The AS-201 uses two distinct identification mechanisms, which should not be confused:
1. Address Code (user-configured via dial switch)
Determines the zone number shown on the keypad:
Zone Number = Address Code + 100
Documented zone range: 100–299.
2. Unique Module Code (factory-assigned, internal to each module)
Used by the panel’s intelligent identification function. If two or more modules are assigned the same code, the panel can automatically reassign the affected module starting from address 399 to resolve the conflict.
This distinction matters for installers configuring multiple AS-201 modules on the same AS-9000 system.
7. Smart Bus-Device Search
After wiring, the panel can automatically detect connected AS-201 modules:
- Complete AS-201 power, bus, and detection-device wiring.
- Access the AS-9000 keypad.
- Enter the Device Management menu.
- Select Search Bus Device.
- The panel searches for and establishes connection with bus expansion modules.
- The keypad displays the number of devices found.
A new search should be run whenever modules are added, removed, or replaced.
8. Applications
- Perimeter Defense — connecting remote alarm detectors at perimeter detection points
- Remote Detection Points — incorporating detection points into an AS-9000 system via the panel bus
- Intrusion Alarm Zone Expansion — adding single-zone capacity to an existing or planned AS-9000 installation
- Security System Expansion Projects — projects requiring additional detection zones within a documented AS-9000 architecture
9. Technical Specifications
| Parameter | Specification |
| Product Model | AS-201 |
| Product Type | Single-Zone Address Module |
| Function | Alarm zone expansion / bus-connected detection-device interface |
| Compatible Panel | AS-9000 Series Alarm Control Panel |
| Communication | Alarm control panel bus |
| Detection Devices | Normally Open (NO) / Normally Closed (NC) |
| Operating Voltage | DC 10–24 V |
| Working Current | 10 mA |
| Dimensions | 60 × 16 × 10 mm |
| Weight | 10 g |
| Working Temperature | -10°C to +50°C |
| Humidity | 0–85% |
| Zone Address Range | 100–299 |
| Zone Number Logic | Address Code + 100 |
| Communication Indicator | Blinking = normal communication |
| Bus Device Search | Supported via panel keypad |
| Duplicate-Code Identification | Supported (auto-reassignment from 399) |
| Warranty | 1 year |
10. Installation & Integration
- Connect AS-201 power, bus and detection-device wiring per Section 5.
- Set the module address code using the on-board dial switch.
- Power the system and confirm the communication indicator is blinking.
- Run Search Bus Device from the AS-9000 keypad (Section 7).
- Confirm the zone number displayed corresponds to Address Code + 100.
- Re-run the bus search after any addition, removal, or replacement of modules.
11. OEM Supply
Athenalarm offers OEM supply for the AS-201. The specific customization scope below distinguishes verified terms from items requiring confirmation.
| OEM Item | Status |
| OEM Supply | Yes |
| OEM MOQ | 200 pcs |
| OEM Lead Time | 15 days |
Buyers requiring specific OEM customization should specify their requirements in the RFQ so that Athenalarm can confirm feasibility, cost, and lead time.
12. B2B Procurement Information
| Procurement Item | Information |
| Standard MOQ | 10 pieces |
| Sample Availability | Yes |
| Sample Lead Time | 10 days |
| Standard Lead Time | 10 days |
| OEM MOQ | 200 pieces |
| OEM Lead Time | 15 days |
| Production Capacity | 5,000 pieces/month |
| Warranty | 1 year |
| Payment Terms | 100% T/T in advance |
| Shipping Terms | EXW / FOB / CIF |
| Packaging | Tape-sealed packaging |
| Technical Support | Yes |
Lead times should be reconfirmed against actual order quantity, customization requirements, and current production schedule at the time of inquiry.
13. Quality Control
| QC Item | Status |
| Inspection Stages (incoming / in-process / final) | 100% inspection |
| Functional Test Procedure | 100% inspection |
| Electrical Test Procedure | 100% inspection |
| Environmental / Aging Test | 100% inspection |
14. Product FAQ
Q1: What is the AS-201?
A single-zone address module used to expand an AS-9000 series alarm-control-panel system and connect a remote detection device through the panel bus.
Q2: Who is the AS-201 designed for?
Importers, distributors, wholesalers, security equipment suppliers, and system integrators sourcing alarm-system expansion components for AS-9000-based projects.
Q3: What alarm control panel is compatible with the AS-201?
The AS-9000 series alarm control panel.
Q4: What is the MOQ?
Standard MOQ is 10 pieces. OEM MOQ is 200 pieces.
Q5: Is OEM supply available?
Yes. OEM MOQ is 200 pieces with a 15-day lead time.
Q6: What is the standard lead time?
10 days for standard orders; 15 days for OEM orders.
Q7: Is a sample available?
Yes, with a 10-day sample lead time.
Q8: What warranty is provided?
1 year.
Q9: Is technical support available?
Yes.
15. Technical FAQ
Q1: How many zones does one AS-201 provide?
One — the AS-201 is a single-zone address module.
Q2: What detection devices can be connected?
Devices with normally open (NO) or normally closed (NC) outputs.
Q3: What is the operating voltage and current?
DC 10–24 V, 10 mA working current.
Q4: How does the AS-201 communicate with the alarm panel?
Through the AS-9000 series alarm control panel bus — a wired, proprietary bus interface, not Ethernet, IP, wireless, or cloud communication.
Q5: How does the panel identify the module?
Via its user-set address code (zone number = address code + 100) and its factory-assigned unique module code, which the panel can detect through a bus-device search.
Q6: What does the blinking communication indicator mean?
Normal module communication.
Q7: What happens if two modules have the same code?
The panel can automatically reassign the affected module’s address starting from 399.
Q8: How is the zone number calculated?
Zone Number = Address Code + 100. Documented range: 100–299.
Q9: Does the AS-201 support Ethernet or IP communication?
No. Only AS-9000 alarm control panel bus communication is documented.
16. Why Source AS-201 from Athenalarm?
- Specialized AS-9000-compatible zone-expansion component with documented bus integration method
- Single-zone expansion with NO/NC detection-device support
- Automatic bus-device search and duplicate-code identification, reducing installation ambiguity
- Compact 60 × 16 × 10 mm form factor
- Standard MOQ of 10 pieces; OEM MOQ of 200 pieces
- 10-day standard lead time; 15-day OEM lead time
- 1-year warranty
- Documented production capacity of 5,000 pieces/month
- 100% inspection prior to shipment
- T/T payment; EXW / FOB / CIF shipping terms
- Technical support available
- AS-9000 series product documentation available on request
17. Request a Quotation
The AS-201 Single-Zone Address Module is available for B2B sourcing for alarm-system expansion and remote detection applications.
If you are an importer, distributor, wholesaler, or system integrator, contact Athenalarm to discuss your project or purchasing requirements.
Please include in your inquiry:
- Required quantity
- Current or planned AS-9000 system configuration
- Detection-device type
- Required delivery schedule
- OEM requirements, if applicable (branding, packaging, customization)
[GET QUOTATION →]
Athenalarm will respond with product and procurement information — including confirmed pricing, and OEM customization feasibility — for evaluation against your project requirements.
18. Download Product Documentation
Access complete technical documents and guides for the Athenalarm AS-201 Single-zone Address Module.